Creates the "Maxwell Erik 'Max' Grablin Act" establishing clearance and safety requirements for elevators installed in private residences.
-
Requires maximum clearance of 3/4 inch for swinging doors and 2 1/4 inches for sliding doors between hoistway doors and landing sills.
-
Mandates horizontal sliding and folding car doors withstand 75 pounds of horizontal force applied to a 4-inch area without permanent deformation exceeding 3/4 inch.
-
Requires spacing between hoistway and car doors to reject a 4-inch-diameter sphere at all points under various door configuration scenarios.
-
Mandates elevator car platforms include an underside safety device that interrupts power and stops downward motion within 2 inches if obstructed, requiring manual reset to resume operation.
-
Applies to all new elevators in private residences and directs the Florida Building Commission to adopt these requirements into the Florida Building Code by October 1, 2016.
-
Takes effect July 1, 2016.