Amends Kentucky Building Code to allow residential buildings (Group R-2 occupancy) up to 6 stories to have a single exit stairway instead of requiring multiple exits
-
Buildings must have no more than 4 dwelling units per floor and provide either an exterior or interior stairway
-
Maximum travel distance of 20 feet from any dwelling unit door to the exit stairway, with overall travel distance not exceeding 125 feet
-
Corridors must separate dwelling unit doors from interior exit stairways; units may open directly onto exterior stairways but not interior ones
-
Exit stairway must be isolated from other building occupancies (except parking garages and occupied roofs), with no unprotected openings within 10 feet and 1-hour fire-resistance rated exit doors required