  • Multiple-family dwellings up to 4 stories (or 3 stories with an occupiable roof) may be built with a single interior exit stairway instead of the typically required two stairways under certain conditions.

  • Buildings must have no more than 4 units per level and a maximum net floor area of 4,000 square feet per level, with exit access travel distance limited to 125 feet from the most remote point.

  • Required fire safety systems include a manual fire alarm, automatic smoke detection with occupant notification, and smoke detectors in all common spaces including corridors, stairways, laundry rooms, and mechanical rooms.

  • Automatic sprinklers in the interior exit stairway must comply with NFPA 2025 standards for combustible stairways, regardless of actual construction type.

  • Elevators cannot open into the single exit stairway enclosure, and no electrical receptacles are permitted within the stairway.