MI HB5570
Bill
Status
2/24/2026
Primary Sponsor
Parker Fairbairn
Click for details
AI Summary
-
Multiple-family dwellings up to 4 stories (or 3 stories with an occupiable roof) may be built with a single interior exit stairway instead of the typically required two stairways under certain conditions.
-
Buildings must have no more than 4 units per level and a maximum net floor area of 4,000 square feet per level, with exit access travel distance limited to 125 feet from the most remote point.
-
Required fire safety systems include a manual fire alarm, automatic smoke detection with occupant notification, and smoke detectors in all common spaces including corridors, stairways, laundry rooms, and mechanical rooms.
-
Automatic sprinklers in the interior exit stairway must comply with NFPA 2025 standards for combustible stairways, regardless of actual construction type.
-
Elevators cannot open into the single exit stairway enclosure, and no electrical receptacles are permitted within the stairway.
Legislative Description
Housing: codes; single exit stairway in multiple-family dwellings; allow under certain conditions. Amends 1972 PA 230 (MCL 125.1501 - 125.1531) by adding sec. 4i.
Housing: other
Last Action
Bill Electronically Reproduced 02/24/2026