Establishes statewide energy efficiency standards for unvented attics and unvented enclosed rafter assemblies in residential construction that override local energy code requirements
-
Requires minimum insulation R-values of 20 for climate zones 2 and 3, and R-26 for climate zone 4, using air impermeable insulation
-
Mandates buildings meet a blower door test result of less than 3.0 ACH50 (air changes per hour at 50 pascals) for air tightness
-
Requires mechanical ventilation systems that do not rely solely on negative pressure, and exposed roof rafters must be wrapped in insulation to at least R-3 if not already covered
-
Requires all heating, cooling, ventilation equipment, and ductwork to be located inside the building's thermal envelope
-
Takes effect September 1, 2025
Legislative Description
Relating to certain energy efficiency performance standards for residential construction.